Maximum Process Pressure
Lower maximum pressure can be due to the process connection
Pressure ratings at 20 °C:
. Tri-Clamp: 10 bar
. Weld-in Ball with PEEK-Seal: 6 bar
. Weld-in Ball with SST-Seal: 40 bar
. Threaded: 40 bar
. Tapered Union with Coupling Nut: 10 bar
Shock and Vibration Resistance
According to DIN EN 60751: 2.8 g peak / 10.500 Hz
Self Heating
0.15 °K/mW when measured per method defined in DIN EN 60751
Insulation Resistance
1,000 MO minimum insulation resistance when measured at 500
Vdc and at room temperature
Sheath Material
321 Stainless Steel with mineral-insulated cable construction
Lead Wire
PTFE insulated, silver coated copper wire
Identification Data
The model and serial numbers are marked on each sensor
Ingress Protection (IP) Ratings
The particular rating is applicable only for complete assemblies
including a connection head and tubular thermowell. IP varies from
65 to 68 due to a wide selection on different connection heads,
DIN A and B size, made of different materials such as aluminium,
polyamide and stainless steel